Integration of microelectronic chips in microfluidic systems on printed circuit board


AU: 
Burdallo, I; Jimenez-Jorquera, C; Fernández-Sánchez, C; Baldi, A
SO: 
JOURNAL OF MICROMECHANICS AND MICROENGINEERING
GTQ Authors: 

Research Lines:

VL: 
22
IS: 
10
BP: 
105022
PY: 
2012
SN: 
0960-1317
IF: 
2.11
Year IF: 
2011
Abstract: 

A new scheme for the integration of small semiconductor transducer chips with microfluidic structures on printed circuit board (PCB) is presented. The proposed approach is based on a packaging technique that yields a large and flat area with small and shallow (∼44 μm deep) openings over the chips. The photocurable encapsulant material used, based on a diacrylate bisphenol A polymer, enables irreversible bonding of polydimethylsiloxane microfluidic structures at moderate temperatures (80 ◦C). This integration scheme enables the insertion of transducer chips in microfluidic systems with a lower added volume than previous schemes. Leakage tests have shown that the bonded structures withstand more than 360 kPa of pressure. A prototype microfluidic system with two detection chips, including one inter-digitated electrode (IDE) chip for conductivity and one ion selective field effect transistor (ISFET) chip for pH, has been implemented and characterized. Good electrical insulation of the chip contacts and silicon edge surfaces from the solution in the microchannels has been achieved. This integration procedure opens the door to the low-cost fabrication of complex analytical microsystems that combine the extraordinary potential of both the microfluidics and silicon microtechnology fields.

DT: 
Article en revistes indexades
Percentil: 
HIGH
Percentil Year: 
2011
Category: 
ENGINEERING, ELECTRICAL & ELECTRONIC